-40%

Bluetooth Fingertip Pulse Oximeter Digital Blood Oxygen SpO2 Monitors+ PCSW CE

$ 9.49

Availability: 16 in stock
  • Country/Region of Manufacture: China
  • Included Probe: No Probe Included
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Condition: New
  • Item must be returned within: 60 Days
  • Intended Use/Discipline: Family Medicine
  • Brand: CONTEC
  • Oximeter Type: Pulse Oximeter Cover & Case
  • Return shipping will be paid by: Buyer
  • Form Factor: Fingertip
  • MPN: 69450401
  • Modified Item: No
  • Refund will be given as: Money Back

    Description

    Instructions:
    CMS50D-BT Pulse Oximeter is a portable equipment adopting advanced technology, it mainly checks SpO2 and PR value through the finger, which provides advanced, non-invasive and scientific means for quantitative measurement of oxygen saturation. With the functions of pedometer and calorie calculation.
    CMS50D-BT Pulse Oximeter is applicable for use in plateau area, community healthcare, oxygen bar, Fitness clubs, physical training room, family and medical institution, etc.
    Features:
    1)Display of SpO2 value.
    2)Display of PR value and bar graph.
    3)Low battery indication.
    4)Automatic storage for SpO2 and PR value.
    5)Sync clock function.
    6)Display of steps, calorie and time.
    7)The pedometer can store data
    8)Display direction can be changed automatically.
    9)Height, weight, target calorie and pedometer sensitivity can be set by the server.
    10)Extra low-power consumption setting.
    11)The device will automatically enter to blank screen state when there is no operation for one minute.
    12)The data stored can be uploaded to APP by Bluetooth, APP will upload the data to CLOUD platform for analyzing.
    Performance:
    SpO2 measurement range: 0%~100%
    Accuracy: 70%~100%: ±2%
    0%~69%: unspecified
    PR measurement range: 30bpm~250bpm
    Accuracy: ±2bpm or ±2%, whichever is greater.
    Resolution:
    SpO2: 1%
    PR: 1bpm
    Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%, whichever is greater.
    Resistance to surrounding light: The deviation between the value measured in the condition
    of man-made light or indoor natural light and that of darkroom is less than ±1%.
    Pedometer measurement:
    Measurement range: 0~65535 steps
    Resolution: one step
    Memory function: record 1000 groups of SpO2 data, 224-day pedometer data.
    Working current: ≤150mA
    Power supply: two “AAA” batteries
    Safety classification: type BF applied part
    Physical Identity:
    Dimension: 58mm(L) × 32mm(W) × 34mm(H)
    Weight: about 52g(including two batteries)
    Certification:
    CE, FDA
    Package included:
    1XCMS50D-BT Bluetooth Fingertip Pulse Oximeter
    1XCarry Case
    1XHanging rope
    1XUser manual